Research Article

OCCUPANTS' COMFORT IN RETAIL BUILDINGS: A REVIEW

1 Department of Architecture Faculty of Architecture Kaduna State University, Kaduna State, Nigeria
2 Department of Architecture, Faculty of Environmental Sciences, Kaduna State University, Nigeria
* Corresponding author: ibiyeyeaidowu@kesj.org.ng
Published: Dec, 2021
Pages: 190-211
Views: 37
Downloads: 17

Abstract

In the bid to improve occupants' thermal comfort while still minimizing energy usage, retailbuildings have been undergoing transformations. New trends in retail building design can benoticed globally, from the adoption of day lighting to the incorporation of natural ventilation. Itwould be expected that these new trends in retail building design would attract research studiesfocused on users' comfort, perceptions and expectation. However, in recent years, comfortstudies in retail buildings have focused mainly on Indoor Air Quality (IAQ), visual and acousticcomfort. Though, few studies have been done with in-depth evaluation of the thermal comfortconditions in retail buildings in particular. There is a need to have a compilation and review ofthese studies in order to encourage more studies to be done and to bring awareness to the issueof sustainability in retail buildings. This paper is thus a review of some of such studies. Relevantliterature was search on popular easily assessable research databases (Google scholar,Scopus, and Science Direct.) this was done using appropriate keywords, and articles related tothe Occupants' comfort in retail buildings were finally selected and reviewed for this study.Although, concerns were raised concerning the practicability of natural ventilation and othersustainable measures to achieve adequate comfort in large retail buildings, some studies havehowever revealed that natural ventilation has a great application potential in large retailbuildings.

References

  1. Abbaszadeh, S., Zagreus, L., Lehrer, D., & Huizenga, C. (2006). Occupant Satisfaction with Indoor Environmental Quality in Green Buildings. Healthy Buildings, 3(Figure 1), 365–370.
  2. Ahmed, A. Z., Rahman, S. A., & Shahrani, S. (2004). CO and CO 2 Concentrations in Naturally-Ventilated Houses in Malaysia. In Plea2004 - The 21st Conference on Passive and Low Energy Architecture. (pp. 19–22). Eindhoven, The Netherlands.
  3. Aizat, I. S., Juliana, J., Norhafizalina, O., Azman, Z. A., & Kamaruzaman, J. (2009). Indoor Air Quality and Sick Building Syndrome in Malaysian Buildings. Global Journal of Health Science, 1(2), 126–135.
  4. Al-Azri, N. A., Zurigat, Y. H., & Al-Rawahi, N. Z. (2013). Development of bioclimatic chart for passive building design. International Journal of Sustainable Energy, 32(6), 713–723. [https://doi.org/10.1080/14786451.2013.813026](https://www.google.com/search?q=https://doi.org/10.1080/14786451.2013.813026)
  5. Al-Azri, N., Zurigat, Y. H., & Al-Rawahi, N. (2013). Selection and assessment of passive cooling techniques for residential buildings in oman using a bioclimatic approach. Journal of Engineering Research, 10(2), 52–68.
  6. Altomonte, S., & Schiavon, S. (2013). Occupant satisfaction in LEED and non-LEED certified buildings. Building and Environment, 68, 66–76. [https://doi.org/10.1016/j.buildenv.2013.06.008](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2013.06.008)
  7. Amal, W. (2014). Architecture as a Second Nature. Journal of sustainable architecture and civil engineering, 7(2), 3–9.
  8. Amodio, M., Dambruoso, P. R., de Gennaro, G., de Gennaro, L., Loiotile, D., Marzocca, A, ... Tutino, M. (2014). Indoor air quality (IAQ) assessment in a multistorey shopping mall by high-spatial-resolution monitoring of volatile organic compounds (VOC). Environmental Science and Pollution Research International, 21(23), 13186–13195. [https://doi.org/10.1007/s11356-014-2544-1](https://www.google.com/search?q=https://doi.org/10.1007/s11356-014-2544-1)
  9. Ashrae. (2004). ANSI/ASHRAE Standard 55-2004:Thermal Environmental Conditions for Human Occupancy (Vol. 2004).
  10. Ashrae. (2010). ASHRAE/CIBSE/USGBC Performance Measurement Protocols for Commercial Buildings. Atlanta, GA: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.
  11. Auliciems, A. (1981). Towards a psycho-physiological model of thermal perception. International Journal of Biometeorology, 25, 109-122.
  12. Awbi, H. B. (1991). Ventilation of buildings. London: E & FN Spon.
  13. Baird, G., & Field, C. (2012). Thermal comfort conditions in sustainable buildings – Results of a worldwide survey of users' perceptions. Renewable Energy, 64, 1–4. [https://doi.org/10.1016/j.renene.2012.01.069](https://www.google.com/search?q=https://doi.org/10.1016/j.renene.2012.01.069)
  14. Baizhan, L., & David, L. (2013). Occupant Behavior and Building Performance. In R. Yao (Ed.), Design and Management of Sustainable Built Environments (pp. 279–302). London: Springer-Verlag.
  15. Baldasano, J. M., Valera, E., & Jiménez, P. (2003). Air quality data from large cities. The Science of the Total Environment. 307(1–3). 141–165. [https://doi.org/10.1016/S0048-9697(02)00537-5](https://www.google.com/search?q=https://doi.org/10.1016/S0048-9697(02)00537-5)
  16. Borgenson, S., & Brager, G. (2011). Comfort standards and variation in exceedance for mixed-mode buildings. Building Research & Information, 39(2), 118–133.
  17. Cândido, C., de Dear, R., Lamberts, R., & Bittencourt, L. (2010). Cooling exposure in hot humid climates: are occupants “addicted” Architectural Science Review, 53(1), 59–64. [https://doi.org/10.3763/asre.2009.0100](https://www.google.com/search?q=https://doi.org/10.3763/asre.2009.0100)
  18. Carrilho da Graça, G., Martins, N. R., & Horta, C. S. (2012). Thermal and airflow simulation of a naturally ventilated shopping mall. Energy and Buildings, 50, 177–188. [https://doi.org/10.1016/j.enbuild.2012.03.037](https://www.google.com/search?q=https://doi.org/10.1016/j.enbuild.2012.03.037)
  19. Charles, K. E. (2003). Fanger's Thermal Comfort and Draught Models. Ottawa, Canada.
  20. Che-Ani, I., Tawil, N. M., Musa, R., Yahaya, H., & Tahir, M. M. (2012). The Architecture Studio of Universiti Kebangsaan Malaysia (UKM): Has the Indoor Environmental Quality Standard Been Achieved Asian Social Science, 8(16), 174–183. [https://doi.org/10.5539/ass.v8n16p174](https://www.google.com/search?q=https://doi.org/10.5539/ass.v8n16p174)
  21. Chen, B., & Kang, J. (2004). Acoustic Comfort in Shopping Mall Atrium Spaces—A Case Study in Sheffield Meadowhall. Architectural Science Review, 47(2), 107–114. [https://doi.org/10.1080/00038628.2004.9697033](https://www.google.com/search?q=https://doi.org/10.1080/00038628.2004.9697033)
  22. Choi, S., Guerin, D., Kim, H.-Y., Brigham, J. K., & Bauer, T. (2014). Indoor Environmental Quality of Classrooms and Student Outcomes: A Path Analysis Approach. Journal of Learning Spaces, 2(2). [https://doi.org/80](https://www.google.com/search?q=https://doi.org/80)
  23. Chow, W., & Fung, W. Y. (1995). Indoor Thermal Environment Survey in Air-Conditioned Shopping Malls in Hong Kong. Indoor Environment, 4, 102–112.
  24. Chun, C., Kwok, A., & Tamura, A. (2004). Thermal comfort in transitional spaces-basic concepts: Literature review and trial measurement. Building and Environment, 39(10), 1187–1192. [https://doi.org/10.1016/j.buildenv.2004.02.003](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2004.02.003)
  25. Chun, C., & Tamura, A. (2005). Thermal comfort in urban transitional spaces. Building and Environment, 40(5), 633–639. [https://doi.org/10.1016/j.buildenv.2004.08.001](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2004.08.001)
  26. Chun, C. Y., & Tamura, A. (1998). Thermal environment and human responses in underground shopping malls vs department stores in Japan. Building and Environment, 33(2–3), 151–158. [https://doi.org/10.1016/S0360-1323(97)00047-4](https://www.google.com/search?q=https://doi.org/10.1016/S0360-1323(97)00047-4)
  27. Daghigh, R. (2009). Thermal Comfort in Naturally Ventilated Office Under Varied Opening Arrangements : Objective and Subjective Approach. European Journal of Scientific Research, 26(2), 260–276.
  28. Dahlan, N. D., & Gital, Y. Y. (2016). Thermal sensations and comfort investigations in transient conditions in tropical office. Applied Ergonomics, 54(May), 169–176. [https://doi.org/10.1016/j.apergo.2015.12.008](https://www.google.com/search?q=https://doi.org/10.1016/j.apergo.2015.12.008)
  29. de Dear, R. (2011). Revisiting an old hypothesis of human thermal perception: alliesthesia. Building Research & Information, 39(2), 108–117. [https://doi.org/10.1080/09613218.2011.552269](https://www.google.com/search?q=https://doi.org/10.1080/09613218.2011.552269)
  30. de Dear, R. J., and Brager, G. S. (1998). Developing an adaptive model of thermal comfort and preference. ASHRAE Transactions, 104(1), 145–167.
  31. de Dear, R. J., and Brager, G. S. (2002). Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55. Energy and Buildings, 34(6), 549–561.
  32. De Giuli, V., Da Pos, O., & De Carli, M. (2012). Indoor environmental quality and pupil perception in Italian primary schools. Building and Environment, 56, 335–345. [https://doi.org/10.1016/j.buildenv.2012.03.024](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2012.03.024)
  33. De Giuli, V., Zecchin, R., Corain, L., & Salmaso, L. (2014). Measurements of indoor environmental conditions in Italian classrooms and their impact on children's comfort. Indoor and Built Environment, 0(0), 1–24. [https://doi.org/10.1177/1420326X14530586](https://www.google.com/search?q=https://doi.org/10.1177/1420326X14530586)
  34. De Giuli, V., Zecchin, R., Salmaso, L., Corain, L., & De Carli, M. (2013). Measured and perceived indoor environmental quality: Padua Hospital case study. Building and Environment, 59, 211–226. [https://doi.org/10.1016/j.buildenv.2012.08.021](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2012.08.021)
  35. Della Crociata, S., Martellotta, F., & Simone, A. (2012). A measurement procedure to assess indoor environment quality for hypermarket workers. Building and Environment, 47(1), 288–299. [https://doi.org/10.1016/j.buildenv.2011.07.011](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2011.07.011)
  36. Della Crociata, S., Simone, A., & Martellotta, F. (2013). Acoustic comfort evaluation for hypermarket workers. Building and Environment, 59, 369–378. [https://doi.org/10.1016/j.buildenv.2012.09.002](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2012.09.002)
  37. Deuble, M. P., & de Dear, R. J. (2012). Mixed-mode buildings: A double standard in occupants' comfort expectations. Building and Environment, 54, 53–60. [https://doi.org/10.1016/j.buildenv.2012.01.021](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2012.01.021)
  38. Drake, S., de Dear, R., Alessi, A., & Deuble, M. (2010). Occupant comfort in naturally ventilated and mixed-mode spaces within air-conditioned offices. Architectural Science Review, 53(3), 297–306. [https://doi.org/10.3763/asre.2010.0021](https://www.google.com/search?q=https://doi.org/10.3763/asre.2010.0021)
  39. Edimansyah, B. A., Rusli, B. N., Naing, L., Azwan, B. A., & Aziah, B. D. (2009). Indoor Air Quality in an automotive assembly plant in Selangor, Malaysia. Southeast Asian Journal of Trop Med Public Health, 40(1), 187–192.
  40. Eusébio, Z., Conceição, Gomes, J. M. M., Antão, N. H., & Lúcio, M. M. J. R. (2012). Application of a developed adaptive model in the evaluation of thermal comfort in ventilated kindergarten occupied spaces. Building and Environment, 50, 190–201. [https://doi.org/10.1016/j.buildenv.2011.10.013](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2011.10.013)
  41. Fadeyi, M. O., Alkhaja, K., Sulayem, M. Bin, & Abu-Hijleh, B. (2014). Evaluation of indoor environmental quality conditions in elementary schools' classrooms in the United Arab Emirates. Frontiers of Architectural Research, 3(2), 166–177. [https://doi.org/10.1016/j.foar.2014.03.001](https://www.google.com/search?q=https://doi.org/10.1016/j.foar.2014.03.001)
  42. Federico, M. (2008). Sustainable Design For Retail Buildings. In 25th Conference on Passive and Low Energy Architecture. Dublin.
  43. Fanger, P.O. (1970) Thermal Comfort. Technical University of Denmark, Laboratory of Heating and Air Conditioning, Danish Technical Press, Copenhagen
  44. Frontczak, M. (2012). Human comfort and self-estimated performance in relation to indoor environmental parameters and building features. Technical University of Denmark.
  45. Givoni, B. (1963). Evaluation of the effect of climate on Man: Development of a New Thermal Index. Hebrew University of Jerusalem, Isreal.
  46. Givoni, B. (1976). Man, Climate and Architecture (2nd ed). London: Applied Science Publishers Ltd.
  47. Givoni, B. (1992). Comfort, climate analysis and building design guidelines. Energy and Buildings, 18(1), 11–23. [https://doi.org/10.1016/0378-7788(92)90047-k](https://www.google.com/search?q=https://doi.org/10.1016/0378-7788(92)90047-k)
  48. Hafizal, M. I. M., Hiroshi, Y., & Goto, T. (2012). Comparative Study of Indoor Environment in Residential Buildings in Hot Humid Climate of Malaysia. World Academy of Science, Engineering and Technology International Journal of Civil, Architectural, Structural and Construction Engineering, 6(11), 95–100.
  49. Heinzerling, D., Schiavon, S., Webster, T., & Arens, E. (2013). Indoor environmental quality assessment models: A literature review and a proposed weighting and classification scheme. Building and Environment, 70, 210–222. [https://doi.org/10.1016/j.buildenv.2013.08.027](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2013.08.027)
  50. Hensen, J. L. M. (1990). Literature review on thermal comfort in transient conditions. Building and Environment, 25(4), 309–316. [https://doi.org/10.1016/0360-1323(90)90004-B](https://www.google.com/search?q=https://doi.org/10.1016/0360-1323(90)90004-B)
  51. Hensen, J. L. M. (1990). Literature review on thermal comfort in transient conditions. Building and Environment, 25(4), 309–316. [https://doi.org/10.1016/0360-1323(90)90004-B](https://www.google.com/search?q=https://doi.org/10.1016/0360-1323(90)90004-B)
  52. Honnekeri, A., Brager, G., Dhaka, S., & Mathur, J. Comfort and adaptation in mixed-mode buildings in a hot-dry climate. In Proceedings of 8th Windsor Conference: Counting the Cost of Comfort in a Changing World (pp. 0–13). Windsor, UK, London. [https://doi.org/10.1016/j.enbuild.2013.06.009.Keywords](https://www.google.com/search?q=https://doi.org/10.1016/j.enbuild.2013.06.009.Keywords)
  53. Hu, J., & Li, N. (2015). Variation of PM2.5 Concentrations in Shopping Malls in Autumn, Changsha. Procedia Engineering, 121, 692–698. [https://doi.org/10.1016/j.proeng.2015.09.006](https://www.google.com/search?q=https://doi.org/10.1016/j.proeng.2015.09.006)
  54. Huang, K., Hwang, R. L., Shih, W., Ho, M., and Liao, H. Y. (2014). Feasibility study of a hybrid ventilated classroom in hot-and- humid climate. In WORLD SB14 (pp. 1–7). Barcelona.
  55. Huang, L., Zhu, Y., Ouyang, Q., & Cao, B. (2012). A study on the effects of thermal, luminous, and acoustic environments on indoor environmental comfort in offices. Building and Environment, 49, 304–309. [https://doi.org/10.1016/j.buildenv.2011.07.022](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2011.07.022)
  56. Humphreys, M. A. (1978). Outdoor temperatures and comfort indoors. Building Research and Practice, 6(2), 92-105.
  57. Hussein, I., & Rahman, H. M. (2009). Field Study on Thermal Comfort in Malaysia. European Journal of Scientific Research, 37(1), 127–145.
  58. Ibiyeye, A. I. (2017). Natural ventilation impacts on selected IEQ parameters and users' satisfaction in Malaysian shopping malls' central spaces (PhD Thesis). Universiti Putra Malaysia, Serdang, Malaysia.
  59. Ibiyeye A. I, Mohd Fakri Zaky Ja'afar, Zalina S, Nur Dalilah Dahlan. (2018). Indoor Environmental Quality performance of mixed-mode ventilated shopping malls in hot-humid climatic region. International Journal of Built Environment and Sustainability (IJBES), 5(3): 187-200
  60. Ismail, A. R., Jusoh, N., Zulkifli, R., Sopian, K., & Deros, B. M. (2009). Thermal comfort assessment: A case study at Malaysian automotive industry. American Journal of Applied Sciences, 6(8), 1495–1501.
  61. Jiang, C., Li, S., Zhang, P., & Wang, J. (2013). Pollution level and seasonal variations of carbonyl compounds, aromatic hydrocarbons and TVOC in a furniture mall in Beijing, China. Building and Environment, 69(July 2010), 227–232. [https://doi.org/10.1016/j.buildenv.2013.08.013](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2013.08.013)
  62. John, N. M., Antônio, T., Reis, L., Lima, M. A. De, Cristina, M., and Lay, D. (2016). Evaluation of a popular shopping mall built to accommodate previous street vendors in downtown porto alegre. International Journal of Architectural Research: ArchNet-IJAR, 10(1), 75-95.
  63. Kamaruzzaman, S. N., Egbu, C. O., Zawawi, E. M. A., Ali, A. S., & Che-Ani, A. I. (2011). The effect of indoor environmental quality on occupants' perception of performance: A case study of refurbished historic buildings in Malaysia. Energy and Buildings, 43, 407–413. [https://doi.org/10.1016/j.enbuild.2010.10.003](https://www.google.com/search?q=https://doi.org/10.1016/j.enbuild.2010.10.003)
  64. Kamaruzzaman, S. N., Egbu, C. O., Zawawi, E. M. A., Karim, S. B. A., & Woon, C. J. (2015). Occupants' satisfaction toward building environmental quality: structural equation modeling approach. Environmental Monitoring and Assessment, 187(5). [https://doi.org/10.1007/s10661-015-4447-0](https://www.google.com/search?q=https://doi.org/10.1007/s10661-015-4447-0)
  65. Karyono, T., Sri, E., Sulistiawan, J., & Triswanti, Y. (2015). Thermal Comfort Studies in Naturally Ventilated Buildings in Jakarta, Indonesia. Buildings, 5(3), 917–932. [https://doi.org/10.3390/buildings5030917](https://www.google.com/search?q=https://doi.org/10.3390/buildings5030917)
  66. Khamidi, M. F., Ngah, S., Wahab, A., Rodzi, M., and Mohd, N. (2013). Post occupancy evaluation (POE) and indoor environmental quality (IEQ) assessment: A case study of universiti teknologi petronas new academic. Journal Design + Built, 6, 1–21.
  67. Kim, J., & de Dear, R. (2012a). Impact of different building ventilation modes on occupant expectations of the main IEQ factors. Building and Environment, 57, 184–193. [https://doi.org/10.1016/j.buildenv.2012.05.003](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2012.05.003)
  68. Kim, J., & de Dear, R. (2012b). Nonlinear relationships between individual IEQ factors and overall workspace satisfaction. Building and Environment, 49, 33–40. [https://doi.org/10.1016/j.buildenv.2011.09.022](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2011.09.022)
  69. Klinmalee, A., Srimongkol, K., & Kim Oanh, N. T. (2009). Indoor air pollution levels in public buildings in Thailand and exposure assessment. Environmental Monitoring and Assessment, 156(1–4), 581–594. [https://doi.org/10.1007/s10661-008-0507-z](https://www.google.com/search?q=https://doi.org/10.1007/s10661-008-0507-z)
  70. Kubba, S. (2010). Indoor Environmental Quality. In LEED Practices, Certification, and Accreditation Handbook (pp. 211–269). Butterworth-Heinemann. [https://doi.org/10.1016/B978-1-85617-691-0.00007-2](https://www.google.com/search?q=https://doi.org/10.1016/B978-1-85617-691-0.00007-2)
  71. Lai, C. K., Mui, K. W., Wong, L. T., & Law, L. Y. (2009). An evaluation model for indoor environmental quality (IEQ) acceptance in residential buildings. Energy and Buildings, 41(9), 930–936. [https://doi.org/10.1016/j.enbuild.2009.03.016](https://www.google.com/search?q=https://doi.org/10.1016/j.enbuild.2009.03.016)
  72. Li, J., Xie, C. J., Yan, L. S., Cai, J., & Xie, P. (2013). Carbonyl Levels and Personal Exposures in Large Shopping Malls of Nanchang, China. Analytical Letters, 46(6), 1025–1043. [https://doi.org/10.1080/00032719.2012.747092](https://www.google.com/search?q=https://doi.org/10.1080/00032719.2012.747092)
  73. Li, Q., You, R., Chen, C., & Yang, X. (2013). A field investigation and comparative study of indoor environmental quality in heritage Chinese rural buildings with thick rammed earth wall. Energy and Buildings, 62, 286–293. [https://doi.org/10.1016/j.enbuild.2013.02.057](https://www.google.com/search?q=https://doi.org/10.1016/j.enbuild.2013.02.057)
  74. Luo, M., Cao, B., Damiens, J., Lin, B., & Zhu, Y. (2014). Evaluating thermal comfort in mixed-mode buildings: A field study in a subtropical climate. Building and Environment, 88, 46–54. [https://doi.org/10.1016/j.buildenv.2014.06.019](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2014.06.019)
  75. Martellotta, F., Simone, A., Della Crociata, S., & D'Alba, M. (2016). Global comfort and indoor environment quality attributes for workers of a hypermarket in Southern Italy. Building and Environment, 95, 355–364. [https://doi.org/10.1016/j.buildenv.2015.09.029](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2015.09.029)
  76. Meng, Q., & Kang, J. (2013). Influence of Social and Behavioural Characteristics of Users on Their Evaluation of Subjective Loudness and Acoustic Comfort in Shopping Malls. PLoS ONE, 8(1). [https://doi.org/10.1371/journal.pone.0054497](https://www.google.com/search?q=https://doi.org/10.1371/journal.pone.0054497)
  77. Mohan, J. (2012). Impact of Indoor Environment Quality on Sick Building Syndrome in Indian Leed Certified Buildings. Engineering Sciences, 5(1), 107–114.
  78. Musa, A. R., Abdullah, N. G., Che-Ani, A. I., Tawil, N. M., & Tahir, M. M. (2012a). Temperature Analysis for Indoor Environmental Quality (IEQ) of UKM Architecture Studio. Procedia - Social and Behavioral Sciences, 60, 318–324. [https://doi.org/10.1016/j.sbspro.2012.09.386](https://www.google.com/search?q=https://doi.org/10.1016/j.sbspro.2012.09.386)
  79. Musa, A. R., Abdullah, N. G., Che-Ani, A. I., Tawil, N. M., & Tahir, M. M. (2012b). Indoor Environmental Quality for UKM Architecture Studio: An Analysis on Lighting Performance. Procedia - Social and Behavioral Sciences, 60(1994), 318–324. [https://doi.org/10.1016/j.sbspro.2012.09.386](https://www.google.com/search?q=https://doi.org/10.1016/j.sbspro.2012.09.386)
  80. Naziatul Syima, M., Kamaruzzaman, S. N., Salleh, N., & Sulaiman, R. (2011). A Correlation Studies of Indoor Environmental Quality ( IEQ ) Towards Productive Workplace. 2nd International Conference on Environmental Science and Technology IPCBEE, 6(Icest), 434–438.
  81. Nguyen, A. T., Singh, M. K., & Reiter, S. (2012). An adaptive thermal comfort model for hot humid South-East Asia. Building and Environment, 56, 291–300. [https://doi.org/10.1016/j.buildenv.2012.03.021](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2012.03.021)
  82. Nicol, F. (2004). Adaptive thermal comfort standards in the hot–humid tropics. Energy and Buildings, 36(7), 628–637. [https://doi.org/10.1016/j.enbuild.2004.01.016](https://www.google.com/search?q=https://doi.org/10.1016/j.enbuild.2004.01.016)
  83. Nicol, J. F., & Humphreys, M. A. (2002). Adaptive thermal comfort and sustainable thermal standards for buildings. Energy and Buildings, 34, 563–572.
  84. Nugroho, A. M., Ahmad, M. H., & Ossen, D. R. (2007). A Preliminary Study of Thermal Comfort in Malaysia's Single Storey Terraced Houses. Journal of Asian Architecture and Building Engineering, 6(1), 175–182. [https://doi.org/10.3130/jaabe.6.175](https://www.google.com/search?q=https://doi.org/10.3130/jaabe.6.175)
  85. Omar, H. A. J. (2012). Importance of daylight as a component of sustainability in shopping mall examples. Cankaya University.
  86. Pearce, M. (2016). Eastgate. Accessed may, 2016[https://www.mickpearce.com/Eastgate.html](https://www.google.com/search?q=https://www.mickpearce.com/Eastgate.html)
  87. Parkinson, T., de Dear, R., & Candido, C. (2012). Perception of Transient Thermal Environments: Pleasure and Alliesthesia. Proceedings of Windsor Conference: Counting the Cost of Comfort in a Changing World, (April), 12–15. Retrieved from [http://nceub.commoncense.info/uploads/W1220](https://www.google.com/search?q=http://nceub.commoncense.info/uploads/W1220) Parkinson.pdf
  88. Parkinson, T., & de Dear, R. J. (2016). Thermal pleasure in built environments: spatial alliesthesia from air movement. Building Research & Information, (March), 1–16. [https://doi.org/10.1080/09613218.2016.1140932](https://www.google.com/search?q=https://doi.org/10.1080/09613218.2016.1140932)
  89. Peeters, L., Dear, R. De, Hensen, J., & D'haeseleer, W. (2009). Thermal comfort in residential buildings: Comfort values and scales for building energy simulation. Applied Energy, 86(5), 772–780. [https://doi.org/10.1016/j.apenergy.2008.07.011](https://www.google.com/search?q=https://doi.org/10.1016/j.apenergy.2008.07.011)
  90. Ramírez, N., Cuadras, A., Rovira, E., Borrull, F., & Marcé, R. (2012). Chronic risk assessment of exposure to volatile organic compounds in the atmosphere near the largest Mediterranean industrial site. Environment International, 39, :200 – 209.
  91. Rupp, R. F., & Ghisi, E. (2014a). Choosing a method of thermal comfort for mixed-mode office buildings located in hot-humid summer climate, (April), 10–13.
  92. Rupp, R. F., & Ghisi, E. (2014b). What is the most adequate method to assess thermal comfort in hybrid commercial buildings located in hot-humid summer climate Renewable and Sustainable Energy Reviews, 29, 449–462. [https://doi.org/10.1016/j.rser.2013.08.102](https://www.google.com/search?q=https://doi.org/10.1016/j.rser.2013.08.102)
  93. Sadafi, N., Salleh, E., Lim, C. H., & Jaafar, Z. (2008). Potential Thermal Impacts of Internal Courtyard in Terrace Houses: A Case Study in Tropical Climate. Journal of Applied Sciences, 8(15), 2770–2775.
  94. Salleh, N. M., Kamaruzzaman, S. N., Riley, M., Ahmad Zawawi, E. M., & Sulaiman, R. (2015). A quantitative evaluation of indoor environmental quality in refurbished kindergarten buildings: A Malaysian case study. Building and Environment, 94, 723–733. [https://doi.org/10.1016/j.buildenv.2015.11.002](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2015.11.002)
  95. Sulaiman, M. A., Yusoff, W. Z. W., Pawi, S., & Kamarudin, W. N. W. (2013). Indoor Environmental Quality (IEQ) of Higher Education Institutions (HEIs): A User Perception Survey. Journal of Clean Energy Technologies, 1(4), 318–321. [https://doi.org/10.7763/JOCET.2013.V1.72](https://www.google.com/search?q=https://doi.org/10.7763/JOCET.2013.V1.72)
  96. Sulaiman, Z., & Mohamed, M. (2011). Indoor Air Quality and Sick Building Syndrome Study at two Selected Libraries in Johor Bahru, Malaysia. Environment Asia, 4(1), 67–74.
  97. Sun, Y., Wang, P., Zhang, Q., Ma, H., Hou, J., & Kong, X. (2015). Indoor Air Pollution and Human Perception in Public Buildings in Tianjin, China. Procedia Engineering, 121, 552–557. [https://doi.org/10.1016/j.proeng.2015.08.1032](https://www.google.com/search?q=https://doi.org/10.1016/j.proeng.2015.08.1032)
  98. Tang, J., Chan, C., Wang, X., Chan, L., Sheng, G., & Fu, J. (2005). Volatile organic compounds in a multi-storey shopping mall in guangzhou, South China. Atmospheric Environment, 39(38), 7374–7383. [https://doi.org/10.1016/j.atmosenv.2005.09.018](https://www.google.com/search?q=https://doi.org/10.1016/j.atmosenv.2005.09.018)
  99. Tao, H., Fan, Y., Li, X., Zhang, Z., & Hou, W. (2015). Investigation of formaldehyde and TVOC in underground malls in Xi'an, China: Concentrations, sources, and affecting factors. Building and Environment, 85, 85–93. [https://doi.org/10.1016/j.buildenv.2014.11.017](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2014.11.017)
  100. Thomas, L. E. (2014). Shifting the norm - towards effective mixed mode buildings. In 30th International PLEA Conference (pp. 1–8). CEPT University, Ahmedabad.
  101. Turunen, M., Toyinbo, O., Putus, T., Nevalainen, A., Shaughnessy, R., & Haverinen-Shaughnessy, U. (2014). Indoor environmental quality in school buildings, and the health and wellbeing of students. International Journal of Hygiene and Environmental Health, 217(7), 733–739. [https://doi.org/10.1016/j.ijheh.2014.03.002](https://www.google.com/search?q=https://doi.org/10.1016/j.ijheh.2014.03.002)
  102. Visitsak, S. (2007). An evaluation of the bioclimatic chart for choosing design strategies for a thermostatically-controlled residence in selected climates. PhD thesis, Texas A&M University.
  103. Wai-Ming, L., Lee, S. C., & Chan, L. Y. (2001). Indoor air quality at nine shopping malls in Hong Kong. Science of The Total Environment, 273(1–3), 27–40. [https://doi.org/10.1016/S0048-9697(00)00833-0](https://www.google.com/search?q=https://doi.org/10.1016/S0048-9697(00)00833-0)
  104. Wan Yusoff, W. Z., & Sulaiman, M. A. (2014). Sustainable Campus: Indoor Environmental Quality (IEQ) Performance Measurement for Malaysian Public Universities. European Journal of Sustainable Development, 3(4), 323–338. [https://doi.org/10.14207/ejsd.2014.v3n4p323](https://www.google.com/search?q=https://doi.org/10.14207/ejsd.2014.v3n4p323)
  105. Wei, S., Sun, Y., Li, M., Lin, W., Zhao, D., Shi, Y., & Yang, H. (2011). Indoor thermal environment evaluations and parametric analyses in naturally ventilated buildings in dry season using a field survey and PMVe-PPDe model. Building and Environment, 46(6), 1275–1283. [https://doi.org/10.1016/j.buildenv.2010.12.012](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2010.12.012)
  106. Wong, N. H., & Huang, B. (2004). Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore. Building and Environment, 39(9), 1115–1123. [https://doi.org/10.1016/j.buildenv.2004.01.024](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2004.01.024)
  107. Wong, S. K., Wai-Chung Lai, L., Ho, D. C.-W., Chau, K.-W., Lo-Kuen Lam, C., & Hung-Fai Ng, C. (2009). Sick building syndrome and perceived indoor environmental quality: A survey of apartment buildings in Hong Kong. Habitat International, 33(4), 463–471. [https://doi.org/10.1016/j.habitatint.2009.03.001](https://www.google.com/search?q=https://doi.org/10.1016/j.habitatint.2009.03.001)
  108. Wu, Y. C., & Mahdavi, A. (2014). Assessment of thermal comfort under transitional conditions. Building and Environment, 76, 30–36. [https://doi.org/10.1016/j.buildenv.2014.03.001](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2014.03.001)
  109. Xiong, J., Lian, Z., & Zhou, X. (2015). Investigation of Subjectively Assessed Health Symptoms and Human Thermal Perceptions in Transient Thermal Environments. Procedia Engineering, 121, 212–216. [https://doi.org/10.1016/j.proeng.2015.08.1056](https://www.google.com/search?q=https://doi.org/10.1016/j.proeng.2015.08.1056)
  110. Xu, Y., Liang, Y., Urquidi, J. R., & Siegel, J. a. (2014). Phthalates and polybrominated diphenyl ethers in retail stores. Atmospheric Environment, 87, 53–64. [https://doi.org/10.1016/j.atmosenv.2014.01.019](https://www.google.com/search?q=https://doi.org/10.1016/j.atmosenv.2014.01.019)
  111. Yang, W., & Zhang, G. (2008). Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China. International Journal of Biometeorology, 52(5), 385–398. [https://doi.org/10.1007/s00484-007-0133-4](https://www.google.com/search?q=https://doi.org/10.1007/s00484-007-0133-4)
  112. Yau, Y. H., Chew, B. T., & Saifullah, A. Z. (2011). A Field Study on Thermal Comfort of Occupants and Acceptable Neutral Temperature at the National Museum in Malaysia. Indoor and Built Environment, 1–12. [https://doi.org/10.1177/1420326X11429976](https://www.google.com/search?q=https://doi.org/10.1177/1420326X11429976)
  113. Yee, T. C. (2014). Indoor environmental quality (IEQ): A case study in Taylor's University, Malaysia. International Journal of Engineering and Applied sciences, 5(07), 1–11.
  114. Zaatari, M., Nirlo, E., Jareemit, D., Crain, N., Srebric, J., & Siegel, J. (2014). Ventilation and indoor air quality in retail stores: A critical review (RP-1596). HVAC&R Research, 20(2), 276–294. [https://doi.org/10.1080/10789669.2013.869126](https://www.google.com/search?q=https://doi.org/10.1080/10789669.2013.869126)
  115. Zhao, M., Kim, Y. S., & Srebric, J. (2015). Occupant perceptions and a health outcome in retail stores. Building and Environment, 93, 385–394. [https://doi.org/10.1016/j.buildenv.2015.05.039](https://www.google.com/search?q=https://doi.org/10.1016/j.buildenv.2015.05.039)
  116. Zhou, J., You, Y., Bai, Z., Hu, Y., Zhang, J., & Zhang, N. (2011). Health risk assessment of personal inhalation exposure to volatile organic compounds in Tianjin, China. Science of The Total Environment, 409(3), 452–459. [https://doi.org/10.1016/j.scitotenv.2010.10.022](https://www.google.com/search?q=https%3A%2F%2Fdoi.org%2F10.1016%2Fj.scitotenv.2010.10.022)
How to Cite

IDOWU, I. A., & Shamang, K. J. (2021). OCCUPANTS' COMFORT IN RETAIL BUILDINGS: A REVIEW. Kaduna State University Environmental Sciences Journal, 2(2), 190-211. https://doi.org/10.66884/kesj.2021.nwb4f8k9

I. A. IDOWU, and K. J. Shamang, "OCCUPANTS' COMFORT IN RETAIL BUILDINGS: A REVIEW," Kaduna State University Environmental Sciences Journal, vol. 2, no. 2, pp. 190-211, December 2021. doi: 10.66884/kesj.2021.nwb4f8k9

Share this article: